The Ultimate Closed Loop Positioning Control
Specifications
- New smaller size for mounting in the door of your panel for better
integration in OEM applications
- Zero-power RAM stores encoder position on loss of power, eliminating
need to recalibrate after power loss.
- Menu driven setup is simple and quick. No programming language required.
- Stall detection as well as a watch dog timer provide protection to
the clutch/brake as well as downstream equipment.
- In Position output with adjustable window provides confirmation that
the drive stopped in position.
CLPC® Model LC Closed Loop Positioning Control
General Specifications Chart
| Electrical |
| Input Power |
85-264
Volts VAC, 47-63 Hz, Single Phase, 100 Watts max., Fused @4
Amps. |
| Encoder
Input |
Six
signals, A A", B B", Z and Z'. 7.2 kHz max. 0-3VDC
(Low), 2-12 VDC (High) |
| Auxillary
Supply |
12
VDC, 1 amp, current limited, Short circuit protected. Used for
Encoder and Home Switch |
| Solid
State Inputs |
Three;
120 VAC and 24 VDC standard, fused @ 3 amps, N.O. - Fault, and
in position. |
| Clutch/Brake
Output |
One;
24 VDC, 1 amp, fused @3 amps. |
| Displays |
16
characters by 2 lines, .22:character height, backlit. |
| LED
Status Indicators |
Five:
Channel A, Channel B, Channel Z, Clutch On, Fault |
| Diagonistics |
Eleven;
Internally tested functions. Error Codes and description displayed
to identify faults. |
| Mechanical |
| Enclosure |
Aluminum/Stainless,
Black anodized, NEMA1, IP20 Enclosure. NEMA 4, IP66 when door
mounted with gasket. |
| Weight |
3.5
Lbs. |
| Dimensions |
6"
by 6" Face, 5 3/4" Deep |
| Environmental |
| Operating
Temperature |
32o
- 140o F (0 - 60o C) |
| Storage
Temperature |
0
- 186o F (-18 - 85sup>o
C) |
| Ambient
Humidity |
90%
non-condensing max. |
| Vibration |
2.5g's,
30 to 200 Hz |
| Programmability |
| Interface |
All
functions adjustable through display panel push buttons. Some
of these functions include; |
| Index
Count |
Up
to 65,535 pulses |
| Manual
Adjust |
+-
1/4 of Maximum Count |
| Encoder
Input Control |
x1,
x2, x4 operation |
| Watchdog
timer |
Off,
100ms to 1 min. in 16 increments |
| Pushbuttons |
Five:
Program, Menu Back, Menu Forward (Fault Reset), Increment and
Decrement. |
| Optional
(MIP/PLS) |
Multiple
Indexing Parameters Groups - Capable of storing up to 16 different
groups. Programmable Limit Switch - Capable of 4 Programmable
Outputs based on position. |